The indoor air quality in data centres has become a major importance with specified standards being established to classify the airborne contaminants and biological influences that may affect any electronic hardware
Situation
Data centerequipmnt like servers, routers and data storage hardware are very sensitive to particulate and corrosive gaseous contaminants the will cause corrosion and oxidation that they require a well-maintained environment. If the equipment was exposed to corrosive conditions, it will cause disastrous and costly consequences if not tackled fast enough
Solution
JAF having the expertise and know how in this industry, can IDENTIFY, ELIMINATE & MONITOR, to cater all the needs of customers. The proposed, 3 effective steps approach shall meet to the industry requirements, most reliable and proven with existing list of project references and case studies.
STEP 1 : IDENTIFY

Reactivity Mesurement Kit
(Corrosion Coupon)
- Measure Air Reactivity as per ANSI/ISA-71.04.2013
- Qualifies & Quantifies the presence of Reactive Gases in the controlled Environment
- Handy tool & Very Reliable method to provide Air Quality Assessment Reports
- Can measure performance of the Chemical Filters installed
- Utilizes constant-current coulometricmethod accordance to ASTM B 825-02 to determine the corrosion rate of the exposed environment
STEP 2 : ELIMINATE

DeaKleen SD/SU/SP/MG
(Synthetic Fibre Pre-Filter)
- G4, M5
- Beverage board, Galvanized steel
- Standard depth 22mm, 44mm and 95mm
- Non-woven cotton synthetic blend
- Intercept is available
- UL certified

Stand Alone Purifier
/Pressurizer
Air Purification Equipment
- Low Noise, Stand-Alone Construction
- Low Power AC or DC fans
- Multiple stages of both particulate and chemical filters
- Customized design based on requirements
- Recommended for Low PPM to PPB levels of contaminants

18CS & 12CS
Cassette Modules
- Available in Plastic construction
- Contemporary, Low Resistance Design
- Optimized Design for Energy Efficient Performance.
- Available in 18” & 12” standard depths
- Suitable to work up to 500FPM (2.54m/s)
- Recommended for Low PPM to PPB levels of contaminants.

TerraComb
Honeycomb Grid
- Latest Technology in Chemical Filter Media
- Very Low Pressure Drop; High Energy Saving Potential
- Available in various specification and sizes
- Can remove wide spectrum of Impurities
- ULTRA LOW DUST Carry Over
- Totally Safe & Non-Toxic Fresh (New) Media
- Suitable for all types of installations, such as Deep Filtration Beds, Cassette & Canister Module equipment systems
- Easy to Install & Replace

MiraCell II
Mini-Pleat Type Medium High Efficiency Filter
- F6, F7, F8, F9
- Dual density, ultra-fine fibreglass
- Available in Beverage board, Water resistant board
- Standard depth 95mm
- UL certified

TerraOxi
Air Purification Media
- Activated Alumina Based Oxidization Media
- Utilizes Chemisorption Method to remove Target Impurities
- Can remove wide spectrum of Impurities
- Most suitable media for all Indoor Air Quality (IAQ) Requirements
- Totally Safe & Non-Toxic Fresh (New) Media
- Suitable for all types of installations, such as Deep Filtration Beds, Cassette & Canister Module equipment systems
- Easy to Install & Replace

TerraOxiBlend
Air Purification Media
- Equal Volume Blend of JAF TerraCarb & TerraOxi
- Activated Alumina Based Oxidization Media; Activated Carbon Based Absortpion Media
- Can remove wide spectrum of Impurities
- Most suitable media for all Indoor Air Quality (IAQ) Requirements
- Totally Safe & Non-Toxic Fresh (New) Media
- Suitable for all types of installations, such as Deep Filtration Beds, Cassette & Canister Module equipment systems
- Easy to Install & Replace
STEP 3 : MONITORING

Reactivity Mesurement Kit
Corrosion Coupon
- Measure Air Reactivity as per ANSI/ISA-71.04.2013
- Qualifies & Quantifies the presence of Reactive Gases in the controlled Environment
- Handy tool & Very Reliable method to provide Air Quality Assessment Reports
- Can measure performance of the Chemical Filters installed
- Utilizes constant-current coulometricmethod accordance to ASTM B 825-02 to determine the corrosion rate of the exposed environment

Environmental Condition Monitor (ECM)
- Corrosion rate of Copper and Silver Sensors as per ANSI/ISA-71.04.2013
- Monitors corrosion rate, relative humidity, temperature and differential pressure
- High sensitivity corrosion rate measurement
- Provides both Digital and Analog outputs
- Optional storage in on-board datalogger that is accessible with PC software

Lab Services
- Monitors media usage for a gas phase filtration system.
- Analysis is capable to predict chemical media’s remaining life
- Information obtained can reflect;
- Existing system’s characteristics and effectiveness
- Replacement cycle necessary for maximum performance.