Pulp & Paper

Raw Pulp, either chemical (or) mechanical (or) electromechanical process, will go through several chemical & mechanical treatments to become Paper. These treatments are most likely to release air contaminating by-products that are risky to the surrounding environment, electronic equipment and sensitive control systems.

The Problem

The air contaminants can be classified into two types. namely Gaseous Contaminants like volatile organic compounds (VOCs). reduced sulfurcompounds (TRS), nitrogen oxides (NOx) and organo-chlorine compounds; and Particulates like fly ash and dust.

It is important to get rid of these air contaminants as even the slightest presence of them will affect the overalIprocess efficiency and product quality.

The Solution

JAF having the expertise and know how in this industry, can IDENTIFY, ELIMINATE & MONITOR, to cater all the needs of customers. The proposed, 3 effective steps approach shall meet to the industry requirements, most reliable and proven with existing list of project references and case studies.

STEP 1: IDENTIFY

Reactivity Measurement Kit

Corrosion Coupon

  • Measure Air Reactivity as per ANSI/ISA-71.04.2013
  • Qualifies & Quantifies the presence of Reactive Gases in the controlled Environment
  • Handy tool & Very Reliable method to provide Air Quality Assessment Reports
  • Can measure performance of the Chemical Filters installed
  • Utilizes constant-current coulometricmethod accordance to ASTM B 825-02 to determine the corrosion rate of the exposed environment

STEP 2: ELIMINATE

DeaKleen EC/SD/SU/SP/MG

Synthetic Fiber Pre-filter

  • G4, M5
  • Beverage board, Galvanized steel
  • Standard depth 22mm, 44mm and 95mm
  • Non-woven cotton synthetic blend
  • Intercept is available
  • UL certified

Side Access Purifier (SAP)

Air Purification Equipment

  • Single & Double Wall Constructions
  • Space Saving Side Access Design
  • Customized Design to suit both Commercial & Industrial Requirements
  • Available with all types of granular media
  • Recommended for Low PPM to PPB levels of contaminants

Stand Alone Purifier/Pressurizer

Air Purification Equipment

  • Low Noise, Stand-Alone Construction
  • Low Power AC or DC fans
  • Multiple stages of both particulate and chemical filters
  • Customized design based on requirements
  • Recommended for Low PPM to PPB levels of contaminants

Deep Bed Purifier (DBP)

Air Purification Equipment

  • Single & Double Wall Constructions
  • Customized Media Bed Design available to suit both Commercial & Industrial Requirements.
  • Redundant fan options available
  • Available with in-built control panels & online monitoring
  • Recommended for High to Low PPM Levels of contaminants

MiraCel II

Mini-Pleat Type Medium High Efficiency Filter

  • F6, F7, F8, F9
  • Dual density, ultra-fine fibreglass
  • Available in Beverage board, Water resistant board
  • Standard depth 95mm
  • UL certified

18CS & 12CS

Cassette Modules

  • Available in Plastic construction
  • Contemporary, Low Resistance Design
  • Optimized Design for Energy Efficient Performance.
  • Available in 18” & 12” standard depths
  • Suitable to work up to 500FPM (2.54m/s)
  • Recommended for Low PPM to PPB levels of contaminants

18CT & 24CT

Canister Modules

  • Available as both Metal and Plastic Construction
  • Contemporary, Low Resistance, Efficient Performance
  • Available in 18” & 24” standard depths
  • Suitable to work up to 500FPM (2.54m/s)
  • Recommended for Low PPM to PPB levels of contaminants

TerraComb

Honeycomb Grid

  • Latest Technology in Chemical Filter Media
  • Very Low Pressure Drop; High Energy Saving Potential
  • Available in various specification and sizes
  • Can remove wide spectrum of Impurities
  • ULTRA LOW DUST Carry Over
  • Totally Safe & Non-Toxic Fresh (New) Media
  • Suitable for all types of installations, such as Deep Filtration Beds, Cassette & Canister Module equipment systems
  • Easy to Install & Replace

TerraCarb Acid

Air Purification Media

  • Coal based Impregnated Activated Carbon
  • Specially Targets Acid Gas Impurities
  • Utilizes Chemisorption method to remove Target Pollutants
  • Can remove Wide Spectrum Impurities
  • Ideal Media to use in typical carbon based systems
  • Totally Safe & Non-Toxic Fresh (New) Media
  • Suitable for all types of installations, such as Deep Filtration Beds, Cassette & Canister Module equipment systems
  • Easy to Install & Replace

TerraOxi Blend

Air Purification Media

  • Equal Volume Blend of JAF TerraCarb & TerraOxi
  • Activated Alumina Based Oxidization Media; Activated Carbon Based Absortpion Media
  • Can remove wide spectrum of Impurities
  • Most suitable media for all Indoor Air Quality (IAQ) Requirements
  • Totally Safe & Non-Toxic Fresh (New) Media
  • Suitable for all types of installations, such as Deep Filtration Beds, Cassette & Canister Module equipment systems
  • Easy to Install & Replace

STEP 3: MONITORING

Reactivity Measurement Kit

Corrosion Coupon

  • Measure Air Reactivity as per ANSI/ISA-71.04.2013
  • Qualifies & Quantifies the presence of Reactive Gases in the controlled Environment
  • Handy tool & Very Reliable method to provide Air Quality Assessment Reports
  • Can measure performance of the Chemical Filters installed
  • Utilizes constant-current coulometricmethod accordance to ASTM B 825-02 to determine the corrosion rate of the exposed environment

Environmental Condition Monitor (ECM)

  • Corrosion rate of Copper and Silver Sensors as per ANSI/ISA-71.04.2013
  • Monitors corrosion rate, relative humidity, temperature and differential pressure
  • High sensitivity corrosion rate measurement
  • Provides both Digital and Analog outputs
  • Optional storage in on-board datalogger that is accessible with PC software

Lab Services

  • Monitors media usage for a gas phase filtration system.
  • Analysis is capable to predict chemical media’s remaining life
  • Information obtained can reflect;
    • Existing system’s characteristics and effectiveness
    • Replacement cycle necessary for maximum performance.